Master Task Register
Filter/search by task code, description, workstream, area, equipment, status, priority, owner, vendor, manual blocker, task dependency, and impact fields. CSV export preserves seed core columns.
Data source: Supabase
Showing Area: Hydrogenation Area — 14 of 241 tasks
| Task | Workstream | Area | Equipment | Description | Status | Priority | Owner | Target | Manual Blocker | Dependency Blocked | Blocked By | Blocking | C Impact | Q Impact |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| PP-0188 | Hydrogenation | Hydrogenation Area | Hydrogen Reactor 250 L | Verify 250 L hydrogen reactor installation | Closed | Critical | Engineering Unassigned | No Target | No | No | 0 | 0 | Yes | Yes |
| PP-0189 | Hydrogenation | Hydrogenation Area | Hydrogenation Area | Complete hydrogenation area utility pipeline work | Work In Progress | Critical | Engineering Mr.Sharma Ji | 2026-08-15 | Yes | No | 0 | 0 | Yes | Yes |
| PP-0190 | Hydrogenation | Hydrogenation Area | Hydrogenation Area | Complete hydrogenation area civil work | Work In Progress | Critical | Engineering Unassigned | No Target | Yes | No | 0 | 0 | Yes | Yes |
| PP-0191 | Hydrogenation | Hydrogenation Area | Hydrogen / Nitrogen Manifold | Obtain quote for hydrogen manifold | Quote Awaited | Critical | Plant Head Mr.Siva | 2026-07-20 | Yes | No | 0 | 0 | Yes | Yes |
| PP-0192 | Hydrogenation | Hydrogenation Area | Hydrogen / Nitrogen Manifold | Obtain quote for nitrogen manifold | Quote Awaited | Critical | Plant Head Mr.Siva | 2026-07-20 | Yes | No | 0 | 0 | Yes | Yes |
| PP-0193 | Hydrogenation | Hydrogenation Area | Hydrogen / Nitrogen Manifold | Issue PO and receive hydrogen / nitrogen manifold materials | Under Discussion | Critical | Plant Head Mr.Siva/Mr.Kailas | 2026-07-24 | Yes | No | 0 | 0 | Yes | Yes |
| PP-0194 | Hydrogenation | Hydrogenation Area | Hydrogen / Nitrogen Manifold | Install hydrogen and nitrogen manifold with tagged valves and regulators | Not Started | Critical | Vendor Mr.Sharma Ji / Vendor | 2026-08-14 | Yes | No | 0 | 0 | Yes | Yes |
| PP-0195 | Hydrogenation | Hydrogenation Area | Hydrogen / Nitrogen Manifold | Perform pressure test, leak test and purge verification for gas manifold | Not Started | Critical | Production Mr.Sharma Ji / Mr.Jain Ji | 2026-08-20 | Yes | No | 0 | 0 | Yes | Yes |
| PP-0196 | Hydrogenation | Hydrogenation Area | Hydrogenation Area | Verify flameproof electrical fittings, earthing and bonding | Not Started | Critical | Electrical / Instrumentation Unassigned | No Target | Yes | No | 0 | 0 | Yes | Yes |
| PP-0197 | Hydrogenation | Hydrogenation Area | Hydrogenation Area | Install/verify hydrogen gas detection and ventilation | Not Started | Critical | EHS / Engineering Unassigned | No Target | Yes | No | 0 | 0 | Yes | Yes |
| PP-0198 | Hydrogenation | Hydrogenation Area | Hydrogenation Area | Prepare purging, inerting and emergency response SOPs | Not Started | Critical | Production / EHS / QA Unassigned | No Target | No | No | 0 | 0 | Yes | Yes |
| PP-0199 | Hydrogenation | Hydrogenation Area | Hydrogenation Area | Complete EHS pre-startup safety review for hydrogenation | Not Started | Critical | EHS Unassigned | No Target | Yes | No | 0 | 0 | Yes | Yes |
| PP-0200 | Hydrogenation | Hydrogenation Area | Hydrogen Reactor 250 L | Execute hydrogen reactor commissioning trial | Not Started | Critical | Vendor Amir Tanks | 2026-08-10 | Yes | No | 0 | 0 | Yes | Yes |
| PP-0201 | Hydrogenation | Hydrogenation Area | Hydrogen Reactor 250 L | Prepare and execute IQ/OQ package for hydrogen reactor | Not Started | Critical | Engineering Mr.Siva / Mr.Jain Ji / Mr.Sharma JI | 2026-08-31 | No | No | 0 | 0 | Yes | Yes |
Imported columns supported: 31. Closed and qualified tasks remain visible unless an open-only filter is selected.